Open Sigmoid Colectomy

Procedure Spotlight

Access & Divide Inferior Mesenteric Artery

Access & Divide Inferior Mesenteric Artery
Product Title Text

ENSEAL X1 Large Jaw

Product Description text

Has a separate seal and cut functionality as designed to provide surgeons the control to manage a variety of surgical tasks.1

Product Image
ENSEAL X1 Large Jaw

Mobilize Distal Sigmoid & Upper Rectum

Mobilize Distal Sigmoid & Upper Rectum
Product Title Text

ENSEAL X1 Large Jaw

Product Description text

Has a separate seal and cut functionality as designed to provide surgeons the control to manage a variety of surgical tasks.1

Product Image
ENSEAL X1 Large Jaw

Transect the Distal Sigmoid or Upper Rectum

Transect the Distal Sigmoid or Upper Rectum
Product Title Text

CONTOUR Curved Cutter Stapler

Product Description text

The CONTOUR Curved Cutter Stapler features one-handed firing, pin-placement, and closure.#,2

Product Image
CONTOUR Curved Cutter Stapler

Create Anastomosis

Create Anastomosis
Product Title Text

ETHICON Circular Stapler

Product Description text

The ETHICON Circular Stapler [ILS] with its Controlled Tissue Compression and Adjustable Height Staple technology is designed to enable surgeons to create a secure anastomosis with effective perfusion to promote healing.3,4

Product Image
ETHICON Circular Stapler

Close Fascia

Close Fascia
Product Title Text

STRATAFIX Symmetric PDS Plus Knotless Tissue Control Device

Product Description text

STRATAFIX Symmetric PDS Plus Knotless Tissue Control Device is an antibacterial (polydioxanone) monofilament, synthetic absorbable device prepared from the polyester, poly (p-dioxanone.)5 The device contains IRGACARE MP (triclosan), a broad spectrum antibacterial agent, at no more than 2360 μg/m.5 STRATAFIX Symmetric PDS Plus Devices are indicated for general soft tissue approximation where use of an absorbable suture is appropriate.5 STRATAFIX Symmetric PDS Plus Device, being absorbable, is not to be used where prolonged (beyond six weeks) approximation of tissue under stress is required and is not to be used in conjunction with prosthetic devices (i.e. heart valves or synthetic grafts.)5 STRATAFIX Symmetric PDS Plus Device should not be used in patients with known allergic reactions to IRGACARE MP (triclosan.)5

Product Image
STRATAFIX Symmetric PDS Plus Knotless Tissue Control Device
References

# Ethicon, 051631-160419, CONTOUR Curved Cutter Stapler, Internal Document (C1347), Data on File.

‡ Registered Trademark of BASF Group.

1. Ethicon Inc, 062953-161108. Based on product attributes and overall design of device. (C2154).

2. Ethicon Inc, DR000142, 40 mm Curved Cutter Stapler Design Verification Matrix-DR000142, Dec 2012, Data on File.
 
3. Ethicon Inc, SCN045048 - Summary of Design Intent for Ethicon Intraluminal Stapler (ILS) to Support Claims, Mar 2016. Data on File (C2001).

4. Ethicon Inc, Endoscopic Curved Intraluminal Stapler, Instructions For Use.

5.  Ethicon, Inc. STRATAFIX Symmetric PDS Plus Knotless Tissue Control Device, Instructions For Use.