The Art of Mapping: Carto Prime in the UK & Ireland

Watch this short video showcasing the Carto Prime features.

CARTO PRIME MODULE V7

Contact Us   for more information, training or a follow up and we will get back to you.

Get in Touch

Coherent Mapping

Coherent Mapping

May Simplify the diagnosis of scar-related complex atrial arrythmias by applying Physiological Constraints on LAT information.1

Picture courtesy of Dr. Simon Fynn, Royal Papworth Hospital, Cambridge

Parallel Mapping

Parallel Mapping

Allows for simultaneous mapping of different arrythmias using the same catheter location.4,5

Picture courtesy of Dr J Keaney & Dr. W. Ashram, Mater Misericordiae University Hospital, Dublin: Two maps of the same tachycardia were created simultaneously, one using the traditional WOI and the other the open window method.

CARTOFINDER™ Module

CARTOFINDER™ Module

Expands the CARTO™ 3 system mapping capabilities to irregular arrythmia, identifying repetitive focal and rotational activations.2

Picture courtesy of Dr. Farwell, Essex Cardiothoracic Centre, Basildon

LAT Histogram

LAT Histogram

The LAT Histogram window provides a graphical representation of the LAT values of all points that contribute to the Activity Map’s LAT colouring.5

Picture courtesy of Dr. Tom Wong, Royal Brompton Hospital, London

LAT Hybrid

LAT Hybrid

Provides increased location accuracy compared to standard PVC mapping by associating the PVC LAT information to it corresponding normal sinus rhythm location.3

Picture courtesy of Dr. Andreas Kyriacou, Northern General Hospital, Sheffield

Map Replay

Map Replay

Enables the creation of multiple maps retrospectively for the purpose of mapping different arrythmia using the same catheter location.5

Picture courtesy of Dr. Tom Wong, Royal Brompton Hospital, London

References
  1. Anter E et al. Activation Mapping With Integration of Vector and Velocity Information Improves the Ability to Identify the Mechanism and Location of Complex Scar-Related Atrial Tachycardias. Circ Arrhythm Electrophysiol. 2018;11:e006536.
  2. Bench testing performed by Biosense Webster, Inc. CARTO® 3 V7 CATROFINDER Algorithm POD Report February 2019. 
  3. Steyers III CM et al.Ablation using 3D maps adjusted for spatial displacement of premature ventricular complexes relative to sinus beats: Improving precision by correcting for the shift. J Cardiovasc Electrophysiol. 2019;1-7.
  4. CARTO® 3 System V7 Parallel Mapping and LAT Hybrid Modules Pre‐Clinical Test Report, REP10670, Jan 2019. 
  5. CARTO® 3 System Instructions for Use, Software Version 7.1.80 

For product details such as indications, contraindications, warnings and precautions please consult the IFU.