ECHELON FLEX™ Powered Vascular Stapler

Only the ECHELON FLEX Powered Vascular Stapler with Advanced Placement Tip gives you a narrower anvil, thinner shaft and more articulation than Endo GIA™ Curved Tip Reload with Tri-Staple™ Technology.

Grampeador Powered Vascular ECHELON FLEX™ PVS

Features & Benefits

  • Incredibly precise

    Incredibly Precise

    Narrower anvil,§ thinner shaftβand more articulation.¥ Watch a PVS Transection during Right Upper Lobectomy with ECHELON FLEX Powered Vascular Stapler. Watch Dr. Zane Hammoud at Henry Ford Hospital in Detroit, MI perform a PV transection during a right upper lobectomy procedure with ECHELON FLEX Powered Vascular Stapler.

  • Superior maneuverability

    Superior Maneuverability

    26% narrower curved, blunt tip anvil vs. Endo GIA™ Tri-Staple.™* Reduce the amount of dissection required around the vessel to place the stapler. Plus, the blunt, curved tip improves visibility and confirms early, precise placement on thoracic vessels.

  • More flexibility during placement

    More Flexibility During Placement

    11% greater articulation in each direction¥ vs Endo GIA™ Tri-Staple™. Only the Powered Vascular Stapler provides a span of 100° (50° in each direction), which may make it easier to navigate in the tight thoracic cavity.

  • Increased freedom of movement

    Increased Freedom of Movement

    The 9mm shaft, which is 26% thinnerβ, offers an unprecedented angle of reach. Thinnest shaft diameter offers a broader angle of reach for 43.8% greater freedom of movement in the tight intercostal spaceβ.

Product Specifications

Product Code

Product Code

Description

 
PVE35A PVE35A 35mm Vascular Linear Cutter 

Resources

Echelon Flex Powered Vascular Stapler
ECHELON FLEX™ Powered Vascular Stapler In-Service
0:07:07
VATS lobectomy feat. Dr Diego Gonzalez Rivas
0:07:33
Left Lower Lobectomy
0:00:59
Robotic left upper lobectomy
0:04:25

Supporting Documentation

Product Support

ECHELON FLEX™ Powered Vascular Stapler Steps to Use

ECHELON FLEX™ Powered Vascular Stapler Fact Sheet

ECHELON FLEX™ Powered Vascular Stapler One Pager

White Paper

Achieving Optimal Performance from the ECHELON FLEX™ Powered Vascular Stapler

References

* Versus leading staplers on the market as of October 2017.

† Compared to the Endo GIA™ Curved Tip Reload with Tri-Staple™ technology.  Based on articulation data from IFUs of each device.

‡ Compared to Endo GIA™ Reload with Tri-Staple™ Technology.

§ Versus leading staplers on the market as of October 2017.

β Approach angles assessed in a virtual CAD environment in the 5th intercostal space.

¥ Compared to the Endo GIA™ Curved Tip Reload with Tri-Staple™ technology.  Based on articulation data from IFUs of each device.

For complete indications, contraindications, warnings, precautions, and adverse reactions, please reference full package insert.