ENSEAL® G2 Articulating Tissue Sealer

Offers secure sealing of vessels up to and including 7mm diameter, as well as lymphatics,* while also providing versatility driven by its articulating shaft.

Selador de Vasos Articulado ENSEAL® G2

Features & Benefits

  • ENSEAL® G2 Articulating Tissue Sealer Card 1

    Secure Sealing at Every Turn

    Unparalleled approach to secure sealing. 110° of articulation and 360° shaft rotation facilitates a perpendicular approach to vessels. Vessels sealed with a perpendicular approach using ENSEAL G2 Articulating Tissue Sealers were shown to be 51% stronger than vessels sealed at a 45° angle

  • ENSEAL® G2 Articulating Tissue Sealer Card 2

    Unprecedented Access

    Unmatched maneuvering for better access. Provides the ability to maneuver around corners and behind structures for better access to tissue, especially in deep or tight spaces.

  • ENSEAL® G2 Articulating Tissue Sealer Card 3

    Do More with ENSEAL G2 Articulating Tissue Sealer

    Versatility in the palm of your hand.  May reduce the number of ports and instrument exchanges needed to access targeted areas.

Product Resources

Resources

ENSEAL G2 Articulating
Success Story: Removal of a Dermoid Cyst During Pregnancy by James Kondrup
0:02:18
Total Laparoscopic Hysterectomy with Kurian Thott, MD
0:06:08
Laparoscopic Supracervical Hysterectomy with James D. Kondrup, MD
0:05:11
Laparoscopic Sleeve Gastrectomy with Santiago Horgan, MD, FACS
0:02:48
Lap Sigmoid Resection with Michael Stamos, MD
0:08:05
Laparoscopic Hand Assisted Sigmoid Colectomy with Walter Peters, MD
0:05:37

Supporting Documentation

Clinical Evidence

Perpendicular Blood Vessel Sealing in Surgical Practice

ENSEAL G2 Tissue Sealers Article: Consistency and Sealing of Advanced Bipolar Tissue Sealers

Clinical Utility of a new articulating Tissue Sealer

Product Support

ENSEAL G2 Articulating Tissue Sealer VAC PAC

ENSEAL G2 Articulating Tissue Sealer Product Brochure

Advanced Bipolar Competitive Comparison

References

†† ENSEAL® devices tested in a benchtop study on 5-7mm porcine carotid arteries. With NSLG2C35A devices, median burst pressures were 51% higher for vessels sealed at a 90° angle compared to vessels sealed at a 45° angle (p=0.0007). With NSLG2S35A devices, mean burst pressures were 29% higher for vessels sealed at a 90° angle compared to vessels sealed at a 45° angle (p=0.001).

*Studies conducted on porcine mesentery. (C157)

For complete indications, contraindications, warnings, precautions, and adverse reactions, please reference full package insert.