ENSEAL® X1 Curved Jaw Tissue Sealer

Designed for use in open or laparoscopic procedures, the ENSEAL X1 Curved Jaw Tissue Sealer is a bipolar electrosurgical instrument that can enable more efficiency than LigaSure™ Maryland.1

ENSEAL® X1 Curved Jaw Tissue Sealer

Features & Benefits

  • More Tissue per Bite

    More Tissue per Bite

    ENSEAL X1 Curved Jaw Tissue Sealer can capture, seal, and transect a longer length of tissue per single activation due to a 16% longer jaw, a 40% wider aperture, and a 19% longer cut length.1

  • ENSEAL X1 Curved Jaw

    Secure Sealing2

    ENSEAL X1 Curved Jaw Tissue Sealer delivers reliable hemostasis on vessels up to and including 7mm.3 In preclinical testing, 100% of vessels sealed by ENSEAL X1 Curved Jaw Tissue Sealer achieved hemostasis on the first pass and maintained hemostasis during an elevated blood pressure challenge.4

  • Enseal X1 - More ease of use

    More Ease of Use

    ENSEAL X1 Curved Jaw Tissue Sealer has separate seal and cut capabilities,5 360º  continuous shaft rotation to enable easy access to targeted tissue,6 conveniently placed control buttons for less hand movement,7 and an ergonomic pistol grip designed to accommodate a wide range of hand sizes.8,9 

Product Resources

Resources

ENSEAL® X1 Curved Jaw
ENSEAL X1 Curved Jaw Tissue Sealer Product Video
0:01:20
ENSEAL X1 Curved Jaw Tissue Sealer In-service Video
0:06:10

Supporting Documentation

Product Support

ENSEAL® X1 Curved Jaw Tissue Sealer Fact Sheet

ENSEAL® X1 Curved Jaw vs. Ligasure™ Maryland

ENSEAL® X1 Portfolio Brochure

Energy Portfolio Brochure

References

†n=38 seals for each device.

1. ENSEAL® X1 Curved Jaw Tissue Sealer can capture, seal and transect a longer length of tissue per single activation due to a 16% (or 3.4mm) longer jaw (p < 0.001), a 40% (or 5.0mm) wider unbiased jaw aperture (p < 0.001) and a 19% (or 3.6mm) longer cut length (p < 0.001) compared to LigaSure™ Maryland (LF1937) (C2841).

2. In benchtop testing on 4-7mm porcine carotid arteries, average burst pressure was 1274mmHg. (C2838)

3. (C2717)

4. Out of 38 vessels sealed in a preclinical study on porcine carotid arteries.  During blood pressure challenge, blood pressure was increased to at least 200mmHg for a minimum of 10 minutes to simulate a hypertensive crisis. (C2734)

5. (C2723)

6. (C2743)

7. (C2735)

8. (C2836)

9. (C2883)

For complete indications, contraindications, warnings, precautions, and adverse reactions, please reference full package insert.