The innovative line of MENTOR® SPECTRUM® Adjustable Saline Breast Implants makes the decision-making process easier than ever. Exclusive to Mentor, it is designed with proprietary technology that consists of a removable fill tube that offers the option for physicians to increase or decrease the size of the implant for up to six months after surgery.

spectrum

Features & Benefits

versatile

Highly Versatile

As the only post-operatively adjustable saline filled breast implant in the United States, the SPECTRUM® family of breast implants offer surgeons greater flexibility and control over their patient’s final aesthetic outcome for up to six months post-surgery. This control allows the clinician to customize the final result to satisfy patient preference and need.

Supporting Documentation

 SPECTRUM® Smooth Round Implants

Catalog #

Temp Vol.

Min. Vol.

Min. Final Vol.

Min. Diam.

Min. Proj.

Max. Final Vol.

Max. Diam.

Proj.

350-1410

125 cc

105 cc

125 cc

9.4 cm

2.7 cm

150 cc

9.3 cm

3.2 cm

350-1420

175 cc

150 cc

175 cc

10.3 cm

3.1 cm

210 cc

10.2 cm

3.8 cm

350-1430

225 cc

190 cc

225 cc

10.8 cm

3.5 cm

270 cc

10.9 cm

4.3 cm

350-1440

275 cc

230 cc

275 cc

11.6 cm

3.8 cm

330 cc

11.5 cm

4.6 cm

350-1450

325 cc

275 cc

325 cc

12.4 cm

4.0 cm

390 cc

12.1 cm

4.9 cm

350-1460

375 cc

320 cc

375 cc

13.5 cm

4.1 cm

450 cc

13.0 cm

4.9 cm

350-1470

425 cc

360 cc

425 cc

14.0 cm

4.2 cm

510 cc

13.7 cm

4.8 cm

350-1480

475 cc

405 cc

475 cc

14.3 cm

4.4 cm

570 cc

13.8 cm

5.4 cm

350-1485

525 cc

450 cc

525 cc

15.0 cm

4.4 cm

630 cc

14.4 cm

5.6 cm

350-1490

575 cc

490 cc

575 cc

14.7 cm

4.8 cm

690 cc

14.2 cm

6.0 cm

SILTEX® CONTOUR PROFILE® SPECTRUM® Implants

Catalog #

Temp Vol.

Min. Vol.

Min. Final Vol.

Min. Width

Min. Height

Min. Proj.

Max. Final Vol.

Max. Width

Max. Height

Max. Proj.

354-2511

275 cc

235 cc

 275 cc

11.5 cm

9.5 cm

5.1 cm

 330 cc

11.1 cm

9.4 cm

6.3 cm

354-2512

350 cc

300 cc

 350 cc

12.3 cm

10.5 cm

5.3 cm

 420 cc

11.9 cm

10.1 cm

6.9 cm

354-2513

450 cc

380 cc

 450 cc

13.2 cm

11.0 cm

6.1 cm

 540 cc

12.7 cm

11.0 cm

7.5 cm

354-2514

550 cc

470 cc

 550 cc

14.0 cm

11.9 cm

6.4 cm

 660 cc

13.7 cm

11.9 cm

7.9 cm

354-2515

650 cc

550 cc

 650 cc

15.0 cm

12.7 cm

6.6 cm

 780 cc

14.5 cm

12.5 cm

8.2 cm

Product Insert Data Sheets

Important Information for Your Patients to Consider

Resources

Product Catalog

References

No applicable peer-reviewed references for this page.

Important Safety Information

MENTOR® MemoryGel® Breast Implants, MENTOR® MemoryShape® Breast Implants, and MENTOR® Saline-filled Breast Implants are indicated for breast augmentation in women (at least 22 years old for MemoryGel® Implants and MemoryShape® Implants, and 18 years old for Saline Implants) or for breast reconstruction. Breast implant surgery should not be performed in women with active infection anywhere in their body, with existing cancer or pre-cancer of their breast who have not received adequate treatment for those conditions, or who are currently pregnant or nursing.

Breast implants are not lifetime devices and breast implantation may not be a one-time surgery. The most common complications for breast augmentation and reconstruction with MemoryGel® Implants include any reoperation, capsular contracture, and implant removal with or without replacement. The most common complications with MemoryShape® Implants for breast augmentation include reoperation for any reason, implant removal with or without replacement, and ptosis. The most common complications with MemoryShape® Implants for breast reconstruction include reoperation for any reason, implant removal with or without replacement, and capsular contracture. A lower risk of complication is rupture. The health consequences of a ruptured silicone gel breast implant have not been fully established. MRI screenings are recommended three years after initial implant surgery and then every two years after to detect silent rupture. The most common complications with MENTOR® Saline-filled Implants include reoperation, implant removal, capsular contracture, breast pain, and implant deflation.

For MemoryGel® Implants, patients should receive a copy of Important Information for Augmentation Patients about MENTOR® MemoryGel® Breast Implants or Important Information for Reconstruction Patients about MENTOR® MemoryGel® Breast Implants. For MemoryShape® Implants, patients should receive a copy of Patient Educational Brochure – Breast Augmentation with MENTOR® MemoryShape® Breast Implants or Patient Educational Brochure – Breast Reconstruction with MENTOR® MemoryShape® Breast Implants, and a copy of Quick Facts about Breast Augmentation & Reconstruction with MENTOR® MemoryShape® Breast Implants. For MENTOR® Saline-filled Implants, patients should receive a copy of Saline-Filled Breast Implants: Making an Informed Decision. Your patient needs to read and understand the information regarding the risks and benefits of breast implants, with an opportunity to consult with you prior to deciding on surgery. The ARTOURA® Breast Tissue Expander or CONTOUR PROFILE® Breast Tissue Expander can be utilized for breast reconstruction after mastectomy, correction of an underdeveloped breast, scar revision, and tissue defect procedures. The expander is intended for temporary subcutaneous or submuscular implantation and is not intended for use beyond six months. Do not use the ARTOURA® Tissue Expander nor CONTOUR PROFILE® Tissue Expander in patients where an MRI may be needed. The device could be moved by the MRI causing pain or displacement, potentially resulting in a revision surgery. The incidence of extrusion of the expander has been shown to increase when the expander has been placed in injured areas.

For detailed indications, contraindications, warnings, and precautions associated with the use of all MENTOR® Implantable Devices, which include MENTOR® Saline-filled Implants, MemoryGel® Implants, MemoryShape® Implants, ARTOURA® Expanders, and CONTOUR PROFILE® Expanders, please refer to the Instructions for Use (IFU) provided with each product or visit www.mentorwwllc.com.

100256-191113