Pediatric LCP® Plate System

The Pediatric LCP®  Plate System is designed for stable fixation of varus, valgus or rotational osteotomies and trauma applications in pediatric orthopaedics and is designed to meet the specific requirements of pediatric orthopaedic surgery.

The Pediatric LCP Plate system offers a wide range of locking compression plates along with a surgical technique specifically developed for the pediatric patient. The Pediatric LCP Plates have a universal design for the left and right femur.  The head of the plate features threaded holes for locking screws that either angle into the femoral neck or angle parallel to the growth plate in the distal femur in place of the traditional angled blade.

In the proximal femur plates, an additional, diverging calcar screw ensures increased fixation in the bone. The 100 ̊ and 110 ̊ plates are designed with an offset for osteotomies.  The 2.7 mm plates have a 6 mm offset, the 3.5 mm plates have an 8 mm offset and the 5.0 mm plates have a 10 mm offset.

Plate shafts feature limited-contact profiles and Combi holes.  The Combi hole combines a dynamic compression unit (DCU) hole with a locking screw hole.  Combi holes provide the choice of axial compression and locking capability throughout the length of the plate shaft.

Pediatric LCP®Plate System

Features & Benefits

Angular stability

Angular stability reduces the risk of primary and secondary loss of correction.  Improved connections between screw and plate, as well as within the cortical bone, make casting unnecessary in the majority of cases. (However, it is recommended when using the 2.7 mm plate.)

Intraoperative correction and flexibility

Initial plate positioning with Kirschner wires allows for intraoperative flexibility and correction. The range of plate sizes, angles and screws lengths allow enhanced patient fit.

Medialization

Additional medicalization can be obtained using the 3.5 mm and 5.0 mm Pediatric LCP Plates, requiring one offset for each plate size.

Low profile

Plate design and locking construct reduce muscle disruption and soft tissue irritation.

Supporting Documentation

Resources

Pediatric LCP® Plate System Inventory Control Form

References

No available references for this product.

Indication Statement

The DePuy Synthes Pediatric LCP Plate System is indicated for fixation of fractures (including pathologic and impending pathologic fractures) and osteotomies of the femur in infants, children, adolescents and small statured adults.

Specific indications for the 100°, 110°, 120°, 130°, 140°, 150° plates include:

  • Varus, valgus, rotational and /or shortening osteotomies
  • Femoral neck and/or pertrochanteric fractures
  • Proximal metaphyseal fractures
  • Diaphyseal fractures
  • Pathologic fractures
  • Prophylactic use for impending pathologic fractures

Specific indications for the 90° plates include:

  • Varus, valgus, rotational and /or shortening osteotomiesc
  • Femoral neck and/or pertrochanteric fractures
  • Proximal and distal metaphyseal fractures
  • Diaphyseal fractures
  • Pathologic fractures
  • Prophylactic use for impending pathologic fractures

113764-190508 DSUS